Scope of the Job

Most remodel plans meet the same two rules: combustible trim must sit a set distance from the opening, and the hearth must reach a set depth in front of it. We measure both before design starts, so mantel height and hearth size are right on paper. Many remodels also switch to gas. Placing an insert in the existing opening runs $2,950 to $5,900; framing a direct-vent unit somewhere new runs $4,700 to $9,450.

Trim and mantel distances set on the drawing first
Hearth depth and width sized to the opening
Stone, tile, plaster or brick facing
Gas conversion with an insert or a new direct-vent unit
Permit noted in the quote where the city needs one

The Numbers a Remodel Has to Respect

A masonry fireplace has a short list of distances that the residential code fixes, and every remodel in Orange has to fit inside them. No wood trim may sit within six inches of the opening. Between six and twelve inches, wood is allowed only if it stays thin, sticking out no more than an eighth of an inch for each inch it sits away from the edge, which is why a deep mantel ends up higher than people expect. The hearth in front has to be noncombustible and run out at least sixteen inches from the opening and eight inches past each side, more for a large opening. Factory-built fireplaces follow their own manual, and those figures can be stricter. When we plan a remodel, we measure your opening first and draw these lines on the wall, so your stone, tile or mantel choice starts from what is allowed rather than finding out at the final inspection.

Much of what we fix in older homes is the result of a remodel that skipped this. A mantel moved down to fit a television above, a hearth cut back to lay new flooring, or wood paneling run right up to the brick are all things an inspector will flag when the house sells. The materials matter too. Natural stone, porcelain and ceramic tile, and masonry veneer can all be used close to the opening when they are set on a noncombustible backer. Wood, many plastics and some engineered panels cannot. A remodel can also change what the firebox can safely do. If you plan to add glass doors or an insert later, the surround should be laid out with that in mind, since the insert may need its own trim kit and its own clearances.

Permits, Scope and How the Price Is Built

Whether a remodel needs a permit depends on what it touches. Refacing an existing masonry surround in new tile usually does not. Rebuilding a hearth, changing the firebox, adding a gas line, or replacing a factory-built unit generally does, and the city of Orange and its neighbors will want to inspect before the work is covered up. We list on the scope which parts of your project fall on which side, so the permit cost and the inspection visits are planned rather than discovered. Where a permit is needed, the drawings and the scope reference the clearances we measured, which tends to make the inspection quick. If your project includes a new gas insert, that part is priced at $2,950 to $5,900 with us, depending on the model and the liner it needs.

The rest of a remodel has no fixed figure, because a refacing in porcelain tile and a full stone surround with a new raised hearth are very different jobs. After we visit and measure, the written scope lists each piece: demolition of the old surround, any repair to the firebox or damper found once it is open, the new backer, the facing material, the hearth and the mantel. Materials you pick yourself are shown separately so you can see what the labor costs. We also note anything inside the fireplace that should be fixed while the surround is open, since a cracked firebox or a broken damper is much cheaper to deal with before new tile goes on. For older houses in Orange and Santa Ana, we take care to fit the new surround to the style of the room.

How Addison Chimney Works Handles the Paperwork

Line-Item Quotes

Each defect priced on its own line before work

Rule Named

Findings tied to NFPA 211, the listing or local code

Permit Steps Listed

Permit fees and inspection visits shown in the quote

Records You Keep

Photos and reports a buyer or insurer can read

Related Code Work

Chimney Sweep

Creosote and soot brushed from the flue, with any code item the sweep turns up written down for you.

Scope and rules

Chimney Inspection

NFPA 211 inspections at the level your situation calls for, written so an owner, buyer or city inspector can follow them.

Scope and rules

Chimney Repair

Repairs scoped against the code items they fix, from broken flue tile and open joints to a crown that lets rain through.

Scope and rules

Fireplace Inspection

The firebox, damper, hearth extension and nearby trim checked against the clearances the fire code sets for a working fireplace.

Scope and rules

Fireplace Repair

Firebox, hearth and damper repairs that bring a fireplace back inside its clearances and safe to light again.

Scope and rules

Chimney Level 2 Inspection

The NFPA 211 level used for a sale, a fuel change or after a quake, with recorded camera footage from inside the flue.

Scope and rules

Chimney Cap Installation

Stainless caps with spark arrestor screens, fitted to the flue and sized to the mesh range the state code sets.

Scope and rules

Chimney Flashing Repair

Step and counter flashing replaced where the roof meets the brick, laid in the order the roofing code expects.

Scope and rules

Chimney Masonry Repair

Brick and mortar repair for the cracks and open joints that fail a chimney inspection, matched to the brick you have.

Scope and rules

Chimney Rebuilds

Partial and full chimney rebuilds drawn up to current code, with the permit and inspection steps set out in the quote.

Scope and rules

Fireplace Cleaning

Ash, soot and stains cleared from the firebox, doors and surround, with a note on any clearance or damage issue we see.

Scope and rules

Gas Fireplace Cleaning

Burner, pilot, glass and outside vent cleaned and checked on gas units, with a carbon monoxide reading in the visit notes.

Scope and rules

Gas Fireplace Repair

Fault finding on gas fireplaces and inserts, repaired with parts the maker lists so the unit keeps its safety approval.

Scope and rules

Fireplace Inserts

Gas inserts installed with the permit, the gas line work and a full-height liner that the city inspector will check.

Scope and rules

Pellet Stove Repair

Pellet stove faults found and fixed, with the vent and clearances checked against the stove's listing before it runs again.

Scope and rules

Wood Stove Repair

Wood stove repairs and pipe corrections that put a stove back inside the clearances printed on its own label.

Scope and rules

Gas Logs

Gas log sets matched to the opening and the gas supply, set up so the rules for vented logs in California are met.

Scope and rules

Chimney Seismic Retrofit

Bracing, anchor straps or a lighter rebuilt top for brick chimneys, planned around the seismic rules our cities apply.

Scope and rules

Chimney Crown Repair

Crown repair or replacement shaped to slope, overhang and clear the flue tile, so the top of the chimney sheds water.

Scope and rules

Dryer Vent Cleaning

Lint cleared from the whole dryer duct, with its length, material and outside hood checked against code limits.

Scope and rules

Chimney Liner Installation

Listed stainless liners sized to the appliance, installed so the flue meets what a permit inspector will check.

Scope and rules

Chimney Leak Repair

Leaks traced to the crown, cap, flashing or brick and repaired, with the source written up for an insurer or a buyer.

Scope and rules

Chimney Waterproofing

A breathable masonry repellent applied to sound brick, after open joints, crown cracks and flashing gaps are closed.

Scope and rules

Chimney Damper Repair

Rusted, stuck or warped dampers repaired or replaced, including dampers that must stay open for gas logs.

Scope and rules

Chimney Chase Cover

Stainless chase covers made to measure for prefab chimneys, with the cross break and drip edge that let them shed water.

Scope and rules
Call (657) 222-6004